PRODUCTS 2018-02-06T09:33:46+00:00

Advanced Technology Pressure and Level Transmitters

CST PRODUCTS

PRESSURE TRANSMITTERS

Pressure Transmitter – Process 1

Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, up to 15,000 psi.
Self-adjusting pressure, temperature and barometric measurements made in real-time.
0.1% full scale accuracy.
FIND OUT MORE

Pressure Transmitter – Process 1 – HYD

Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, up to 15,000 psi. Self-adjusting pressure, temperature and barometric measurements made in real-time.
Gold-coated sensor head for Hydrogen Service.
0.1% full-scale accuracy.
FIND OUT MORE

Pressure Transmitter – Process 2

Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
0.25% full scale accuracy.
FIND OUT MORE

Pressure Transmitter – Process 2 – HYD

Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
Gold-coated sensor head for Hydrogen Service.
0.25% full scale accuracy.
FIND OUT MORE

Pressure Transmitter – Process 3

General Purpose, re-calibration capability, zero and span adjustment, vacuum to 15,000 psi.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 3 – HYD

General Purpose, re-calibration capability, zero and span adjustment, up to 15,000 psi.
Gold-coated sensor head for Hydrogen Service.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 4

Intrinsically Safe Zone 2 Division 2 locations, recalibration capability, zero and span adjustment, up to 15,000 psi.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 4 – HYD

Intrinsically Safe Zone 2 Division 2 locations, recalibration capability, zero and span adjustment, up to 15,000 psi.
Gold-coated sensor head for Hydrogen Service.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 5

High Pressure, General Purpose, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 5 – HYD

High Pressure, General Purpose, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
Gold-coated sensor head for Hydrogen Service.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 6

High Pressure and Intrinsically Safe Zone 2 Division 2 locations, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000 psi and 30,000 psi.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter – Process 6 – HYD

High Pressure and Intrinsically Safe Zone 2 Division 2 locations, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000psi and 30,000 psi.
Gold-coated sensor head for Hydrogen Service.
0.25% BSL accuracy.
FIND OUT MORE

Pressure Transmitter-Process 7

General Purpose economy pressure transmitter, up to 10,000 psi.

Low cost.
0.5% BSL accuracy.
FIND OUT MORE

DIFFERENTIAL PRESSURE TRANSMITTERS

Differential Pressure Transmitter – Process 8

Differential Pressure – Advanced Technology, intrinsically safe, intelligent, HART™ enabled, up to 1,000 psi.
Self-adjusting pressure, temperature and barometric measurements made in real-time.
0.1% full scale accuracy
FIND OUT MORE

Differential Pressure Transmitter – Process 8 – HYD

Differential Pressure – Advanced Technology, intrinsically safe, intelligent, HART™ enabled, up to 1,000 psi.
Self-adjusting pressure, temperature and barometric measurements made in real-time.
Gold-coated sensor head for Hydrogen Service.
0.1% full scale accuracy
FIND OUT MORE

Differential Pressure Transmitter – Process 9

Differential Pressure – General Purpose, re-calibration capability, zero and span adjustment, up to 1,000 psi.
0.25% BSL accuracy.
FIND OUT MORE

Differential Pressure Transmitter – Process 9 – IS

Differential Pressure – Intrinsically Safe Zone 2 Division 2 locations, re-calibration capability, zero and span adjustment, up to 1,000 psi.
0.25% BSL accuracy.
FIND OUT MORE

Differential Pressure Transmitter – Process 9 – IS – HYD

Differential Pressure – Intrinsically Safe Zone 2 Division 2 locations, re-calibration capability, zero and span adjustment, up to 1,000 psi.
Gold-coated sensor head for Hydrogen Service.
0.25% BSL accuracy.
FIND OUT MORE