Pressure Transmitters
Pressure Transmitter – Process 1
- Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, up to 10,000 psi.
- Self-adjusting pressure, temperature and barometric measurements made in real-time.
- 0.075% full scale accuracy.
Pressure Transmitter – Process 1 – HYD
- Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, up to 10,000 psi. Self-adjusting pressure, temperature and barometric measurements made in real-time.
- 316SS sensor head for Hydrogen Service.
- 0.075% full scale accuracy.
Pressure Transmitter – Process 2
- Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
- 0.25% full scale accuracy.
Pressure Transmitter – Process 2 – HYD
- Advanced Technology, intrinsically safe Zone 0 locations, intelligent, HART™ enabled, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
- 316SS sensor head for Hydrogen Service.
- 0.25% full scale accuracy.
Pressure Transmitter – Process 3
- General Purpose, re-calibration capability, zero and span adjustment, vacuum to 10,000 psi.
- 0.25% BSL accuracy.
Pressure Transmitter – Process 4
- Increased Safety for Class I, Div. 2, Zone 2 hazardous locations, recalibration capability, zero and span adjustment, up to 10,000 psi.
- 0.25% BSL accuracy.
Pressure Transmitter – Process 4 – HYD
- Increased Safety for Class I, Div. 2, Zone 2 hazardous locations, recalibration capability, zero and span adjustment, up to 10,000 psi.
- 316SS sensor head for Hydrogen Service.
- 0.25% BSL accuracy.
Pressure Transmitter – Process 5
- High Pressure, General Purpose, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000 psi and 30,000 psi with Autoclave ¼” F250C connection.
- 0.25% BSL accuracy.
Pressure Transmitter – Process 6
- High Pressure and Increased Safety for Class I, Div. 2, Zone 2 hazardous locations, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000 psi and 30,000 psi.
- 0.25% BSL accuracy.
Pressure Transmitter – Process 6 – HYD
- High Pressure and Increased Safety for Class I, Div. 2, Zone 2 hazardous locations, re-calibration capability, zero and span adjustment, 15,000 psi, 20,000psi and 30,000 psi.
- 316SS sensor head for Hydrogen Service.
- 0.25% BSL accuracy.
Pressure Transmitter-Process 7
- General Purpose economy pressure transmitter, up to 10,000 psi.
- Low cost.
- 0.5% BSL accuracy.